Recovery unit Value VRR12L
MANUAL
Economical recovery with 3/ 4 HP, oil-less compressor
Suitable for all commonly used refrigerants including R410A
ARI& CE certification approved
Characteristic
Value
Refrigerants
Category III: R12, R134a, R401C, R406A, R500.
Category IV: R22, R401A, R401B, R402B, R407C, R407D,
R408A, R409A, R411A, R411B, R412B, R502, R509.
Category V: R402A, R404A, R407A, R407B, R410A, R507.
Power supply
220V/ 50Hz
Motor
3/ 4 HP
Motor speed
1450 rpm @ 50 Hz
Maximal current draw
5A @ 220V
compressor
Oli-less, Air-cooled, 1-piston style
Automatic safety Shut-off
38.5 bar / 3850 kPa ( 558 psi)
Recovery rate
Category III
Category IV
Category V
Vapor
0.23 kg/ min.
0.25 kg/ min.
0.26 kg/ min.
Liquid
1.57 kg/ min.
1.80 kg/ min.
2.20 kg/ min.
Push/ pull
4.64 kg/ min.
5.57 kg/ min.
6.22 kg/ min.
Operating temperature
0° C - 40° C
Dimensions
400 x 250 x 355 mm